beautypg.com

S-registers – Multi-Tech Systems MT3334ZDX User Manual

Page 37

background image

3 - AT Commands, S-Registers and Result Codes

37

Register:

S5

Unit:

decimal

Range:

0-32, 33-127

Default:

8(^H)

Description:

Sets ASCII code for the backspacecharacter.

Values greater than 32 disable the backspace
character.

Register:

S6

Unit:

seconds

Range:

2-65

Default:

2

Description:

Sets the time the modem waits after it goes off-

hook before it begins to dial the telephone number.

Register:

S7

Unit:

seconds

Range:

1-255

Default:

50

Description:

Sets the time the modem waits for a carrier signal

before aborting a call. Also sets the wait for silence
time for the @ dial modifier.

Register:

S8

Unit:

seconds

Range:

0-65

Default:

2

Description:

Sets the length of a pause caused by a comma

character in a dialing command.

Register:

S9

Unit:

ASCII

Range:

0-127

Default:

0

Description:

Defines Remote Configuration Escape Character.

Register:

S10

Unit:

100ms

Range:

1-254

Default:

20

Description:

Sets how long a carrier signal must be lost before

the modem disconnects.

This manual is related to the following products: