beautypg.com

Multi-Tech Systems MTASR3-200 User Manual

Page 64

background image

RASFinder User Guide

MTASR3-200

64

Command:

X

n

Result Code Selection

Values:

n = 0–7

Default:

4

Description:

X0

Basic result codes (

e.g., CONNECT); does not look for dial tone or busy signal.

X1

Extended result codes (

CONNECT 56000 V42bis, CONNECT 33600 V42bis, etc.); does not look

for dial tone or busy signal.

X2

Extended result codes with

NO DIALTONE; does not look for busy signal.

X3

Extended result codes with

BUSY; does not look for dial tone.

X4

Extended result codes with

NO DIALTONE and BUSY.

X5

Extended result codes with

NO DIALTONE and BUSY.

X6

Extended result codes with

NO DIALTONE and BUSY.

X7

Basic result codes with

NO DIALTONE and BUSY.

Command:

Y

n

Long Space Disconnect

Values:

n = 0

Default:

0

Description:

Y0

Disable sending or responding to long space break signal on disconnect.

Y1

Enable sending or responding to long space break signal on disconnect. (Not supported.)

Command:

Z

n

Modem Reset

Values:

n = 0 or 1

Default:

None

Description:

Z0

Reset modem to profile saved by the last

&W command.

Z1

Same as Z0.

Command:

&B

n

V.32 Auto Retrain

Values:

n = 1

Default:

1

Description:

&B0

Disable V.32 auto retrain. (Not supported.)

&B1

Enable V.32 auto retrain.

Command:

&C

n

Data Carrier Detect (DCD) Control

Values:

n = 0 or 1

Default:

1

Description:

&C0

Force Data Carrier Detect signal high.

&C1

Let Data Carrier Detect follow carrier signal.

Command:

&D

n

Data Terminal Ready (DTR) Control

Values:

n = 0, 1, 2, or 3

Default:

2

Description:

&D0

Modem ignores DTR signal.

&D1

When DTR drops while in online data mode, the modem enters command mode, issues an OK,
and remains connected.

&D2

When DTR drops while in online data mode, the modem hangs up.

&D3

When DTR drops, the modem hangs up and resets as if an ATZ command were issued.

Command:

&F

n

Load Factory Default Settings

Values:

n = 0

Default:

None

Description:

&F0

Load factory settings as active configuration.

Command:

&G

n

V.22bis Guard Tone Control

Values:

n = 0, 1, or 2

Default:

0

Description:

&G0

Disable guard tone.

&G1

Enable 550 Hz guard tone.

&G2

Enable 1800 Hz guard tone.

*

:

The