Modem S-Registers

S-registers are small regions of memory where modem configuration

information is stored. Whereas AT commands tell a modem what to do, S-

registers tell the modem how to do it. Each S-register has a name that

consists of the letter S and a number (S0, S1, S2, etc.), hence the term S-

register. Use the Sr? command to read the value stored in an S-register and
the Sr=n command to change it.

S0

Number of Rings Until Modem Answers
Unit: 1 ring

Range: 0–255

Default: 0

Defines number of rings the modem waits before answering an incoming

call. Default value is zero, which effectively disables the auto-answer

function. When auto-answer is disabled, the modem can only answer via the

ATA command. Set the S0 register value to one to cause the modem to

answer the call immediately after the first ring. Maximum number of rings

that can be configured is 255.

S1

Ring Count
Unit: 1 ring

Range: 0–255

Default: 0

Counts number of rings that have occurred. It is a read type of register and

is seldom used in typical operation. Each time an incoming ring signal is

detected, S1 increases its value by one, up to a maximum of 255. If you set

S1 to a value other than its default value of zero, or if the value is increasing

with rings, this new value remains stored in S1 for eight seconds after the

last ring is counted, after which the value reverts back to zero.

S2

Escape Code Character
Unit: Decimal

Range: 0–255

Default: 43 (+)

Defines escape code character by its decimal ASCII code. Default character

is the plus (+) sign (decimal 43). S2 can be set for any ASCII character.