Circuit Breakers

Three thermal circuit breakers are located inside the top of the Console.

Fig. 34 — Circuit Breaker location

Under normal circumstances circuit breakers do not require service; they are
automatically re-set when an overload condition is corrected. If a breaker is
cycling on/off, locate the cause of the electrical overload and repair as required.

Maximum Cut Depth Adjustment

This saw comes factory-adjusted for maximum usable cut depth. However,
should you desire to change this setting:

1. Park the blade-less saw on a flat and level surface.
2. Fully lower the saw onto the Stop Bolts

(see Fig. 35)

.

3. Measure the distance from the Blade Collars to the surface.
4. Adjust the Stop Bolts in or out until the Blade Collars have 1/8” to 3/16”

ground clearance.

5. Ensure that both bolts are adjusted to the same settings so the load is evenly

distributed.

Remove Panel to
access circuit
breakers