90D0093

7

Parlor Vent Free Fireplace

GETTING STARTED

Make sure you have received all parts:
Check your packing list to verify that all listed parts have
been received. You should have the following:

Unvented gas heater

Ceramic fiber logs

Two () anchoring screws

Installation/operating instructions

Millivolt controlled heater designed to be operated with
optional devices for ON/OFF functions.

Hand held Remote with receiver

Wall T-stat with 0' wire

Wall switch with 0' wire

Hand held Thermostat Remote w/receiver

PREINSTALLATION INFORMATION

Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance. Do not
attempt to install any part of the appliance unless you
have all parts in good condition.
What you will need for installation:
You must have the following items available before pro-
ceeding with installation:

External regulator (for propane/LPG only)

Manual shutoff valve

Piping which complies with local codes

Sediment trap

Phillips head screwdriver

Tee joint.

Pipe sealant approved for use with propane/LPG

(Resistant to sulfur compounds)

Pipe wrench

W

ARNING

Gloves are recommended when handling

ceramic fiber logs to prevent skin irritation
from loose fibers. Logs are fragile —
handle with care.

In planning the installation for the fireplace it is necessary
to determine where the unit is to be installed and whether
optional accessories are desired. Gas supply piping should
also be planned. The following steps represent the normal
sequence of installation. Each installation is unique, how-
ever, and might require a different sequence.
1. Position fireplace in desired location. Refer to the Loca-

tion of Fireplace and Clearances and Height Require-
ments
, and Fireplace and Framing Dimensions sections
found in this manual.

NOTE: Be sure all packing material has been removed

from under the unit.

. Install following the instructions found in this manual.
3. Field wire main power supply to light kit. Refer to the

Electrical Section found in this manual. (Electrical con-
nections should only be performed by an experienced,
licensed certified tradesman).

4. Install optional ON/OFF kit on units with millivolt control.

Refer to the installation instructions included with the
kit and also refer to the Electrical Wiring section found
in this manual.

5. Plumb gas line. Refer to the Connecting the Gas sec-

tion found in this
manual. (Gas connections should only be performed
by an experienced,
licensed/certified tradesman).

6. Complete finish wall material and/or surround.

W

ARNING

Do not install the heater:

Where curtains, furniture, clothing, or

other flammable objects are less than
42" from the front of the heater.

In high traffic areas.

In windy or drafty areas.