Page 42: Resetting the brew unit’s basic position

Resetting the brew unit’s basic
position:
^ Press on the latch, a, and press the
funnel down,
b.
^ Push the connection piece to the far
left,
c.
^ Press "PRESS" once.
The basic position shown above is
reset and the brew unit can be set back
into the machine.
Change the gaskets
^ Change the gaskets if a leak occurs.
Three gaskets are enclosed with the
machine. One gasket is located
between the steam nozzle and the
sleeve. The other two gaskets are
located behind the brew unit at the
water feed tube.
Coffee system care