Multi-Tech Systems RAS96 User Manual
Page 58

RAS96 RASCard User Guide
CommPlete Communications Server
50
2. Enter the E1SETUP command to change the configuration information. At the A:#
prompt type E1setup xy and hit Enter (xy is the CC9600 slot number. For
example, type E1setup 9b to re-provision the E1-1 card.
A:\#e1setup 9b
Use Settings from:
1.
Use Active Settings (pre-configured card)
2.
User System Defaults (new card)
3.
Use Stored Settings (swapping cards)
Enter Selection (q(uit), <1>): 1
Getting E1 Card Info..
1.
Channel Polling Interval (Sec):20
2.
Error Threshold :10
3.
Disconnect Timeout (sec):11
4.
Framing Format : CRC4
5.
Line Coding: Alternate Mark Inversion (AMI)
6.
Signal Options : R2 MF
7.
DNIS-digits(1-64 or 0 for auto) : 0
8.
Country Selection : ITU
9.
Line Buildout : 120 Ohm
Enter Selection (-(previous), q(uit), d(one), <1>): -
A:\#e1setup 9b
Use settings from:
1.
Use Active Settings (pre-configured card)
2.
User System Defaults (new card)
3.
User Stored Settings (swapping cards)
Enter Selection (q(uit), <1>): 2
1.
Channel Polling Interval (Sec) : 20
2.
Error Threshold : 10
3.
Disconnect Timeout (sec) : 11
4.
Framing Format: CRC4
5.
Line Coding: Alternate Mark Inversion (AMI)
6.
Signal Options : R2 Digital
7.
DNIS-digits (1-64 or 0 for auto): 0
8.
Country Selection : ITU
9.
Line Buildout : 120 Ohm
Enter Selection (-(previous), q(uit), d(one), <1>): -