Enting, Equirements – Monessen Hearth B-Vent Specialty Gas Fireplace System DESIGNER SERIES User Manual

Page 11

background image

V

ENTING

R

EQUIREMENTS

10

W

ARNING

: D

O

NOT

CONNECT

THIS

APPLIANCE

TO

A

CHIMNEY

FLUE

SERVING

A

SEPARATE

SOLID

FUEL

BURNING

APPLIANCE

.

C

ARBON

DEPOSITS

(S

OOT

)

AND

CREOSOTE

FROM

SOLID

FUELS

CAN

CLOG

THE

VENT

FROM

THE

APPLIANCE

CAUSING

POISONOUS

CARBON

MONOXIDE

TO

BE

RELEASED

INTO

THE

ROOM

IN

WHICH

THE

APPLIANCE

IS

INSTALLED

.

All vented gas-fired appliances when operating correctly produce small concentrations of carbon monoxide
along with other combustion products. Should something interfere with the operation of the appliance,
it is possible for the appliance to produce deadly quantities of poisonous carbon monoxide. A

LL

FLUE

PRODUCTS

FROM

THIS

APPLIANCE

MUST

BE

VENTED

TO

THE

OUTSIDE

AT

ALL

TIMES

.

NEVER

OPERATE

AN

APPLIANCE

DESIGNED

TO

BE

VENTED

WITHOUT

A

CORRECTLY

WORKING

VENT

SYSTEM

CONNECTED

TO

THE

APPLIANCE

.

W

ARNING

: V

ENTING

OF

THIS

APPLIANCE

IS

ONE

FO

THE

MOST

IMPORTANT

PARTS

OF

THE

INSTALLATION

. V

ENTING

SYSTEMS

MUST

BE

INSTALLED

AND

INSPECTED

ACCORDING

TO

THESE

ISNTRUCTIONS

AND

LOCAL

CODES

OR

IN

THE

ABSENCE

OF

LOCAL

CODES

,

ACCORDING

TO

THE

N

ATIONAL

F

UEL

G

AS

C

ODE

Z223.1 - L

ATEST

EDITION

,

BY

A

LICENSED

OR

OTHERWISE

QUALIFED

INSTALLER

.

Your local gas company should have copies of the National Fuel Code Z223.1 or other installation codes
applicable to your area.

Venting requirements and accepted methods vary greatly depending on the particular installation. It is
impossible to thoroughly define all possible installation circumstances in this manual. The following
instructions and illustrations are general guidelines only. A

LL

VENTING

MATERIAL

MUST

BE

INSTATLLED

ACCORDING

TO

LOCAL

CODES

,

OR

IN

THE

ABSENCE

OF

SUCH

CODES

,

ACCORDING

TO

THE

N

ATIONAL

F

UEL

G

AS

C

ODE

Z223.1.

W

ARNING

: A

N

IMPROPERLY

VENTED

GAS

-

FIRED

APPLIANCE

CAN

LEAD

TO

DEATH

FROM

CARBON

MONOXIDE

POSIONING

.

Venting materials are not provided with this appliance and must be purchased separately.

This appliance must be installed using 6" type “B” vent.

N

OTE

: T

RANSITION

REQUIRED

.

53D9019.

Rev 3 11/07