Programming the Control

CONTROL SETTINGS REQUIRED

upon installation

and after an extended power outage.

NOTES:

WHEN THE TRANSFORMER IS PLUGGED INTO
THE ELECTRICAL OUTLET, 12:00 PM (flashing),
and an arrow

is displayed next to PRESENT TIME

on the faceplate decal. The blue indicator light will
also flash. Program the control as instructed below.

If

- - - is flashing,

use the UP

button to set

the correct F or H code as follows: F35 for GXSF35E
or F39 for GXSF39E. If you pass by the correct code
number, use the DOWN

button. Then press the

MODE button to accept the correct model.

A “beep” sounds while pressing buttons for control
programming. One beep signals a change in the
control display. Repeated beeps mean the control
will not accept a change from the button you have
pressed, and you should select another button.

To program the control, you will use the UP

,

DOWN and

MODE buttons.

Use the MODE button to scroll arrow

to desired

control function.

SET PRESENT TIME OF DAY

1. Press the MODE button until

arrow points

to

PRESENT

TIME.

2. Press UP

or DOWN

button to set. The UP button

advances the time; the DOWN button moves the time
in reverse.

2.

If the present time is between noon and midnight,
be sure PM shows in the display. If the present time
is between midnight and noon, be sure AM shows in
the display.

NOTE: Each press of an UP

or DOWN

button changes

the time by one minute. Holding the button changes the
time at a rapid rate.

3. When the present time is correct, press MODE to accept.

SET WATER HARDNESS NUMBER

1. Press the MODE button until

arrow points

to

HARDNESS.

2. Press UP

or DOWN

button

to set your water hardness number in the display. DOWN
decreases the hardness value. UP increases the hardness
value.

NOTE: Each press of a button changes the display by 1,
between 1 and 25. Above 25, the display changes 5 at a time
(25, 30, 35, etc.). Holding a button in changes the numbers
at a rapid rate.

3. When the display shows your water hardness (in grains

per gallon), press MODE to accept.

NOTE: If there is clear water iron in your water supply,
you will need to increase the hardness setting by 5 for
each 1 ppm of clear water iron in your water supply.

You can get the grains per gallon (gpg) hardness of your
water supply from a water analysis laboratory. If you are
on a municipal supply, call your local water department.
Or call Legend Technical Services, an independent
laboratory, to request a water hardness test kit at
1.800.826.8553, extension 47. If your report shows
hardness in parts per million (ppm) or milligrams per liter
(mg/l), simply divide by 17.1 to get the equivalent number
of grains per gallon.

SET RECHARGE (STARTING) TIME

1. Press the MODE button until

arrow points

to

RECHARGE

TIME.

NOTE: A flashing 2:00 AM (factory default) should show in
the display. This is a good time for recharge to start (takes
about 2 hours) in most households because water is not
in use. HARD WATER is bypassed to house faucets during
recharge.

If no change is needed, go to step 3.

To change the

recharge starting time, follow step 2.

2. Press UP

or DOWN

button to set the desired

recharge start time. Be sure to observe the AM or PM
as you did when setting the time of day.

NOTE: Each press of a button changes the time by 1 hour.
Holding the buttons in changes the time at a rapid rate.

3. Press the MODE button to accept.

SALT

LEVEL

PM

SALT

LEVEL

SALT

LEVEL

AM