beautypg.com

Service: set model (f or h) code – GE GXSF39E User Manual

Page 17

background image

17

GEAppliances.com

1. To enter diagnostics, press and hold

the MODE button for 3 seconds until
the LOW SALT ALARM screen shows.

2. Press the MODE button 2 times to

advance through LOW SALT ALARM
and SALT EFFICIENCY options. See
Programming the Control for details
on these two options.

3. OPERATION OF DIAGNOSTICS

• Valve Position—Press the RECHARGE

button to

initiate a recharge cycle. Press again to manually index
valve to next position. See Service: Manually Advance
Recharge Check
for details.

0 – Service
1 – Fill
2 – Brine
3 – Backwash
4 – Fast Rinse

• Motor Operation—Two dashes will circulate around

when motor should be running.

• Position Switch Operation—

– Closed—valve rotating to next position

– Open—valve in position, service, fill, brine, etc.

• Water Meter—Indicates whether water is flowing

through valve.

– 000 indicates no water is flowing through the valve

– Open nearby soft water faucet

– 000 to 199 (continual) shows water is flowing. Display

repeats for each gallon of water passing through the
meter. Control will beep at every gallon.

– If there is no reading in the display, with faucet

open, check the sensor. Pull the sensor from the
valve outlet port, and pass a small magnet in front
of the sensor. Counter should index in the display.
If counter does not index, check to make sure
harness is connected to board properly. If there is
a reading in the display, there may be a problem
associated with the turbine. Turn off water supply,
close the by-pass valve, and disconnect by-pass valve
from valve body. Check turbine for binding or
restriction due to debris. If this does not correct
the problem, the Timer, Sensor or Turbine may
require replacement.

4. Historical data about the softener is available.

Press and hold the UP

button to display the number

of days this control has had electrical power applied.

Press and hold the DOWN

button to display the

number of recharges initiated by this control since the
model code number was entered.

5. Press the MODE button to return to normal operation

and display.

Service: Set Model (F or H) Code

1. To change or check model code, first press and hold the

MODE button for 3 seconds until the LOW SALT ALARM
screen shows.

2. Press and hold the MODE button again

for 3 seconds. A display with

at

the top will appear.

3. Press the UP

or DOWN

buttons

to select the correct model code.

SR22–GXSF27E, F31–GXSF31E, F35–GXSF35E,
F39–GXSF39E, H39–GXSH39E, H45–GNSH45E

4. Press the MODE button one time to return to normal

operation and display. If the model code was changed:

the display will go blank momentarily, then display the

model code entered.

the display will then return to the set present time

display, and the blue indicator light will flash. The
control will have to be reprogrammed. See Programming
the Control
.

NOTE: If the control is left in any of the above diagnostic
displays, or a flashing display when setting time, hardness,
etc., it will revert back to the normal display in 4 minutes.

Service: Manually Initiated Electronics Diagnostics

SALT

LEVEL

SALT

LEVEL

SALT

LEVEL

Water meter

Valve
position

Position
switch

Motor

Motor

Turbine

Turbine support
and shaft

Sensor
housing

Position
switch

Valve
outlet

SALT

LEVEL

This manual is related to the following products: