The third line, "2. Type" allows system events to be mapped to contact closure
output channels:
• Transmitted. The contact behaves normally.
• Optic A: A problem on optic port A closes the selected contact.
• Optic B: A problem on optic port B closes the selected contact.
• Optic A or B: A problem on either optic port closes the selected contact.
• Video X: Loss of video on the specified video input channel
(where X is the video channel) closes the selected contact.
• Video W,X,Y,Z: Loss of video on any of the specified video input channels
(where W,X,Y,Z are the video channels) closes the selected contact.
The fourth line, "3. Force" allows a contact output to be forced into a known
state for test:
• None: The test is disabled and the contact behaves normally.
• Open: The contact is forced open.
• Closed: The contact is forced closed.
When leaving this menu with test patterns enabled, a warning message comes up
alerting that the test states have been disabled to allow real contact closure
information to pass.
Main -> Local -> Power:
This menu displays the measured voltages of the selected power supply. It also indicates
the status of the power supply (Pass/ Fail). Use "+" to select the next power supply. Use "-
" to select the previous power supply. Press "left" to exit this menu.
Main -> Local -> Test:
Various tests can be selected from the sub-menus.
Power Supply: A Pass
+
5V
-5V
+12V
-12V
5.2
-4.9
11.9
-12.3
B
Test Menu
1. LED/LCD/Alarm
2. Temp
3. Video