beautypg.com

Adjustments – Grindmaster SHUTTLE BREWER APBVSA-430V2E230 User Manual

Page 7

background image

Shuttle Brewers & Airpot/Shuttle Brewers

Page 7

Adjustments

All adjustments to machine are accessible through the front display(s). Refer to specifics below and the
Programming Routine section. All values are preset at the factory and may vary brewer to brewer.

Temperature Adjustment

Tank temperature can be adjusted from 170°F – 205°F (77°C – 96°C) through the front display. See Programming
Routine section for procedure.

Altitude (ft)

Approximate Boiling Point

Recommended Max. Temperature

°F

°C

°F

°C

0

212

100

205

96.1

500

211.1

99.5

204

95.6

1000

210.2

99.0

203

95.0

1500

209.3

98.5

202

94.4

2000

208.4

98.0

201

93.9

2500

207.5

97.5

200

93.3

3000

206.6

97.0

199

92.8

3500

205.7

96.5

199

92.8

4000

204.8

96.0

198

92.2

4500

203.9

95.5

197

91.7

5000

203

95.0

196

91.1

5500

202

94.4

195

90.6

6000

201.1

93.9

194

90.0

6500

200.2

93.4

193

89.4

7000

199.3

92.9

192

88.9

7500

198.3

92.4

191

88.3

This brewer can be set for maximum water temperature of 205°F (96°C). The boiling point of water is lower as
altitude increases. The setpoint temperature of the brewer should be maintained below the boiling point at a given
elevation. Refer the to the chart below for recommended maximum setpoint for given altitudes.

THERMISTOR CURVE FOR PART # A725-097

°C

°F

RESISTANCE (OHMS)

°C

°F

RESISTANCE (OHMS)

0

32

16325

60

140

1244

5

41

12697

65

149

1041

10

50

9951

70

158

875

15

59

7856

75

167

740

20

68

6246

80

176

628

25

77

5000

85

185

535

30

86

4028

90

194

458

35

95

3266

95

203

393

40

104

2663

100

212

339

45

113

2185

105

221

294

50

122

1802

110

230

255

55

131

1493