Troubleshooting (cont.)

Brewing Problems

Problem

Possible Causes

Service Check

Remedy

Brew volume too
large or too small

• Sprayhead clogged.

• Brew valves clogged

with lime deposits.

• Water supply pressure

or flow rate not
adequate.

• Visually check for

clogging of holes
in brewhead.

• Visually inspect

brew valve at
hose connections.

• Check to see that fill

valve cycles on and
off frequently during
brew cycle when all
brew heads are used
simultaneously. Check
to ensure that water
supply line is 3/8” and
pressure is between
30 and 80 psi (207 and
552 KPA).

• Clean all holes.

• Clean lime from valve. Seat,

cup or entire valve may need
replacement.

• Supply water at adequate

pressure and flow rate.

Brew volume
erratic

• Water supply pressure

fluctuates.

• Check water pressure

with and without other
appliances operating.

• Plumb water supply so that

water pressure is not
significantly affected by
other appliances.

Brew cycle will
not start

• Optional momentary

switch to indicate

container in place not
engaged or faulty.

• Brew circuit connections

not secure.

• Brew valve faulty.

• Touchpad faulty.

• Check to see that

container fully engages
switch. Check for
continuity across switch
when switch is engaged.

• Check to see that

connector (6-pin)
is securely connected to
control board. Check to
see that all connections
from controller through
brew valve are secure.

• Check to see if there is

24 Vac across brew valve
terminals.

• Check to see that

touchpad connections
to control board are
secure.

• If fully engaged switch does

not complete circuit across
terminals of switch, replace
switch.

• Secure connections.

• If there is 24 Vac across

terminals and brew valve is
not open, replace valve.

• If connections are secure,

other functions appear normal
and touchpad will not initiate a
brew cycle, replace touchpad.

Note: Small variations from batch to batch are normal.