Troubleshooting (cont.), Filling problems, Heating problems – Grindmaster SHUTTLE BREWER APBVSA-430V2E230 User Manual
Page 22
Page 22
Shuttle Brewers & Airpot/Shuttle Brewers
Troubleshooting (cont.)
Filling Problems
Problem
Possible Causes
Service Check
Remedy
Tank does not refill
• Fill valve or control
board is faulty
• Check to ensure proper
connection between
6 pin connector and con-
trol board. Check
for proper connections
at fill valve terminals.
Drain 1 gal. (3.8L) of
water from hot water
faucet. Check for 24 Vac
across fill valve
terminals.
• If 6 pin connector is securely
attached to control board and
all connections are secure
and there is 24 Vac across
fill valve terminals, replace
fill valve.
Heating Problems
Problem
Possible Causes
Service Check
Remedy
Tank does not heat
• No electrical power to
equipment
• No power to control
board
• Check for proper voltage
at terminal block. Check
circuit breaker on supply
circuit.
• Check for proper voltage
across transformer
primary terminals by
disconnecting terminals.
See wiring diagram for
more information.
• Establish electrical power
to unit.
• If there is not proper voltage
across primary, proceed to step
entitled “No power to control
board and transformer not
powered”. If there is proper
voltage across primary, proceed
to step entitled “No power
to control board and
transformer powered”.
- SHUTTLE BREWER APBIC-330V2E230 SHUTTLE BREWER APBIC-430V2 SHUTTLE BREWER APBVSA-330V2 SHUTTLE BREWER APB-430V2 SHUTTLE BREWER APB-330V2 SHUTTLE BREWER APB-430V2E230 SHUTTLE BREWER APBIC-330V2 SHUTTLE BREWER APBIC-430V2E230 SHUTTLE BREWER APBVSA-430V2 SHUTTLE BREWER APBVSA-330V2E230 SHUTTLE BREWER APB-330V2E230