beautypg.com

Troubleshooting (cont.), Filling problems – Grindmaster SHUTTLE BREWER APBVSA-430V2E230 User Manual

Page 21

background image

Shuttle Brewers & Airpot/Shuttle Brewers

Page 21

Troubleshooting (cont.)

Filling Problems

Problem

Possible Causes

Service Check

Remedy

Tank does not refill

• No electrical power to

equipment

• No water supplied to

equipment

• No power to control

board

• No power to control

board and transformer
not powered.

• No power to control

board and transformer
powered.

• Check for proper

voltage at terminal
block. Check circuit
breaker on supply circuit.

• Disconnect water supply

line and ensure that
water is provided to unit.
Check to see that any
and all valves in water
line are open.

• Check for proper voltage

across transformer
primary terminals by
disconnecting terminals.
See wiring diagram for
more information.

• Ensure there is proper

voltage across terminal
block. Check wiring
diagram for more
information.

• Disconnect quick

disconnect on secondary
side of transformer at
quick disconnect
between yellow and blue
wires. Check for 24 Vac
between blue and
yellow wires.

• Establish electrical power

to unit.

• Establish water supply

to unit.

• If there is not 120V across

primary, proceed to step
entitled “No power to control
board and transformer not
powered.”
If there is proper
voltage across primary, proceed
to step entitled “No power
to control board and
transformer powered”.

• Secure connections and reset

circuit breaker on equipment.

• If there is not 24 Vac between

the blue and yellow wires,
replace transformer. If proper
voltage exists, secure

connection between 3 pin
connector and control board.