Control terminals – GE AV-300i User Manual

Page 9

background image

9

3. Control Terminals

1

2

3

4

5

6

7

8

9

12

13

14

15

16

18

19

BU-

External braking

unit (optional)

Strip X1

F unction

max

Programmable / configurable analog differential input. Signal: terminal 1.

Reference point: terminal 2. Default setting: Ramp ref 1

±

10V

Programmable / configurable analog differential input. Signal: terminal 3.

@ 0.25mA

Reference point: terminal 4. Default setting: none

(20 mA when

Programmable / configurable analog differential input. Signal: terminal 5.

current ref

input)

Reference point: terminal 6. Default setting: none. (1)

+10VDC

Reference voltage +10V; Reference point: terminal 9

+10V/10 mA

-10VDC

Reference voltage -10V ; Reference point: terminal 9

-10V/10 mA

0V

Internal 0V and reference point for

±

10V

-

Enable drive

Drive enable: 0V or open; drive disabled; +15…+30V: Drive enabled

+30V

Start

Drive start command: 0V or open: No start; +15…+30V: Start

3.2 mA@15V

F ast stop

OV or open: Fast stop. +15…+30V; No Fast stop.

5 mA@24V

External fault

OV or open: External fault. +15…+30V; No External fault

6.4 mA@30V

COMD I/O

Reference point for digital inputs and outputs, term.12...15, 36...39, 41...42

-

0V24

Reference point for +24V OUT supply, terminal 19

-

+24VDC

+24V supply output. Reference points: terminals 18 or 27 or 28

+22…28V

120 mA@24V

Analog input 1

Analog input 2

Analog input 3

Analog output

1

Program. analog output; def. setting: Motor speed. Ref. point: term. 22

±

10V/5 mA

0V

Internal 0V and reference point for terminals 21 and 23

-

Analog output

2

Program. analog output; def. setting: Motor current. Ref. point: term. 22

±

10V/5 mA

BU comm.

output

VeCon controlled BU-... braking units command. Ref. point: term. 27.

+28V/15 mA

0V24

Reference point for BU-...command ,terminal 26

-

RESERVED

-

Digital input1

+30V

Digital input2

3.2 mA@15V

Digital input3

5 mA@24V

Digital input4

6.4 mA@30V

Digital output

1

+30V/40 mA

Digitaloutput

2

Supply DO

Supply input for digital outputs on terminals 41/42. Ref. point: term.16.

+30V/80 mA

Motor PTC

1.5mA

Programmable digital output; default setting: none

Motor PTC sensing for overtemperature (cutoff R1k if used)

Programmable digital input; default setting: none

21

22

23

26

27

28

29

36

37

38

39

41

42

46

78

79

R1K

Strip X2

F unction

max curr.

250VAC

1A, AC11

250VAC

1A, AC11

OK relay

contact

Potential-relay contact configurable (relay2).
Default: open 0 drive stopped

R elay 2
contact

Potential-relay contact OK relay (closed=OK)

80

82

83

85