5.2 JUMPERS setting
Encoder/Jumpers setting
S11
S12
S13
S14
S15
S16
S17
S18
S19
S20
S21
S22
S23
DE
OFF
OFF
OFF
OFF
OFF
OFF
ON(*)
-
-
-
-
-
-
SE
ON
ON
ON
ON
ON
ON
-
-
-
-
-
B
B
SESC
ON
ON
ON
ON
ON
ON
-
A
A
A
A
A
A
DEHS
OFF
OFF
OFF
OFF
OFF
OFF
ON(*)
B
B
B
B
B
B
ai3150
-
DE: 5V digital incremental encoder with A /A, B / B, C / C
-
SE: 5V sinusoidal incremental encoder with A /A, B / B, C / C
-
DEHS: 5V digital incremental encoder with A /A, B / B, C / C and three Hall sensor digital position signals (for AC
Brushless motors)
-
SESC: 5V sinusoidal incremental encoder with A /A, B / B, C / C and and two sin/cos traces for absolute position
(for AC Brushless motors or positioning)
(*) If the encoder is not provided with the zero channel, S17=OFF
List of jumpers and dip-switch
Designation
F unction
F actory setting
S0
The setting must not be changed
OFF
S1
The setting must not be changed
OFF
S5-S6
Terminating resistor for the serial interface RS485
ON
ON=Termination resistor IN
OFF=Noterminationresistor
S8
Adaptation of the input signal of analog input 1 (terminals 1 and 2)
OFF
ON=0...20mA/4...20mA
OFF=0...10V/-10...+10V
S9
Adaptation of the input signal of analog input 2 (terminals 3 and 4)
OFF
ON=0...20mA/4...20mA
OFF=0...10V/-10...+10V
S10
Adaptation of the input signal of analog input 3 (terminals 5 and 6)
OFF
ON=0...20mA/4...20mA
OFF=0...10V/-10...+10V
S11-S12-S13
Encodersetting
OFF
S14-S15-S16
ON= Sinusoidal SE or SESC encoder (see above)
OFF=Digital DE or DEHS encoder (see above)
S17
Monitoring of the C-channel of the digital encoder
OFF
ON=C-Channel monitored
OFF=C-Channel not monitored (required for single-ended channels)
S18-S19
Encodersetting
B
S20-S21
Pos.A=digital DEHS encoder (see above)
Pos.B=sinusoidalSESCencoder (see above)
S22-S23
Analog input 3 enabling (alternative with SESC encoder)
A
Pos.A=enabled
Pos.B=disabled
S24
Jumper to disconnect 0V (of 24V) from ground
ON
ON=0V connected to ground
OFF=0V disconnected from ground
S25
Jumper to disconnect 0V (regulation section) from ground
ON
ON=0V connected to ground
OFF=0V disconnected from ground
ai4060