Installation preparation – GE Monogram ZEM200WV User Manual

Page 7

background image

ZEM200WV
In-wall
installation
(continued)

ZEM200WV
Under-cabinet
mounting

Installation Preparation

Mic r owav e Oven

• When cabinet depth is a critical factor, receptacle

should be installed in a side wall at rear of opening:
– 14 -5/8" minimum cabinet depth is required.

Receptacle installed in side

wall.

Receptacle installed behind

oven, flush with wall.

• If receptacle is located behind oven, install receptacle

flush with wall to minimize depth:
– 16" minimum depth is required.

Receptacle installed behind

oven, extended into cabinet.

• If receptacle is located behind oven and extended

into cabinet:
– 18" minimum cabinet depth is required.

• A 3-prong grounded receptacle must be within reach

of the oven’s 57" power cord, but located out of view
when oven is installed.

• Allow access for plugging and unplugging; do not

place receptacle directly behind oven.

7