Advanced troubleshooting – GE GNPR40L User Manual

Page 26

background image

Problem

Possible Causes

What To Do

Run out of soft water

Incorrect injector

With water pressure > 70 psi, use 4 bump injectors

between regenerations

(WS15X10059).

Improper regeneration

Repeat regeneration, making certain correct salt dosage is

used.

Fouled resin bed

Use resin cleaner.

Incorrect salt dose and capacity setting • Set Salt per Regen and Capacity setting to proper level. Refer to

the Programming the Control sections.

Incorrect hardness

Set to correct hardness. Refer to the Programming the

Control sections.

Water hardness has increased

Set to new value. Refer to the Programming the Control

sections.

Restricted meter turbine rotation due

Remove bypass, free up turbine and flush with clean

to foreign material in meter housing

water. Turbine should spin freely—if not, replace meter.

Water usage below 1/5 gallon

Repair leaky plumbing and/or fixtures.

per minute

Brine draw value from Advanced

Set correct brine draw value.

Programming Parameters table is
incorrect

Incorrect salt type or use of grid plate • Do not use block salt or grid plate (salt shelf) in brine tank.
(salt shelf)

Control does not draw

Low water pressure

Increase water pressure (20 psi at conditioner).

brine

Restricted drain line

Remove obstruction.

Injector or injector screen is plugged

Clean injector and screen. Refer to the Cleaning the Injector and

Screen section.

Injector defective

Replace injector and cap.

Valve disc 3 and/or 5 not closed

Manually operate cam gear to flush out foreign matter holding

disc open. Replace if needed.

Air check valve prematurely closed

Briefly put control into brine refill status. Refer to the Manual

Regeneration section. Repair air check valve if needed.

Brine tank overflow

Brine valve disc 1 held open

Manually operate cam gear to flush out foreign matter holding

disc open.

Valve disc 2 not closed during brine

Manually operate cam gear to flush out foreign matter holding

draw, causing brine refill

disc open.

Air leak in brine line to air check

Check all connections in brine line for leaks.

Salt setting too high

Set in new values. Refer to Advanced Programming section.

Float assembly malfunctions

Inspect float assembly in brine well for proper operation.

It must be able to move freely.

Intermittent or irregular

Low water pressure

Increase water pressure (20 psi at conditioner).

brine draw

Defective injector

Replace both injector and injector cap.

No conditioned water

Unit did not regenerate

Check for power.

after regeneration

No salt in brine tank

Add salt to brine tank.

Plugged injector

Remove injector and flush it and injector screen.

Air check valve closed prematurely

Put control momentarily into REFILL to free air check. Replace

or repair air check as needed.

Incorrect salt type or use of grid plate

Do not use block salt or grid plate (salt shelf) in brine tank.

(salt shelf) in brine tank

Control backwashes at

Incorrect backwash controller

Replace with correct size controller.

excessively low or high

Foreign matter affecting controller

Remove and clean controller.

rate

operation

26

Advanced troubleshooting.