Problem

Possible Causes

What To Do

Water hard sometimes

Using hot water while the water

• Avoid using hot water during water softening system

softening system is regenerating

regeneration because the water heater will refill with hard water.

Control HARDNESS number setting

• Press the SET button to enter a new value. Be sure the

too low

number shown is the same as the actual grains per gallon
hardness of your water supply. See the Programming
the Control
section if a change in the setting is needed.

Grains of hardness in your water

• Water hardness can change over time, especially in well water.

supply have increased

To check, have the water tested by a water analysis laboratory
or call your local water department. Adjust the hardness
number setting as needed.

System capacity inputs, Salt per

• See Salt per Regen and Capacity section so system will

Regeneration and Capacity set too low

regenerate about every 5 days. See instructions on pages 12
and 13.

If resin bed is fully exhausted, for

• Complete “back to back” regenerations. Initiate Regeneration

example, after a malfunction, one

cycle, wait 1 minute, then press REGEN again.

regeneration cycle may not fully

See page 14.

restore capacity

Water feels slippery

Absence of hardness minerals

• This is normal. Hardness in water gives it the abrasive feel

after installation of

you may have been accustomed to. The slippery feel is the

water softening system

clean feel of soft water.

Water softening system

Water softening system is a

• Does not use much salt to regenerate—very efficient.

not using any salt

“demand” unit

Possible salt bridge

• See the Breaking a Salt Bridge section.

Possible plugged injector and screen

• See the Cleaning the Injector and Screen section.

Water is blue color

Acidic water in copper plumbing

• Have the water tested at once.

after water softening
system was installed

Cloudiness on glassware Combination of soft water and

• This is called etching and is permanent. To prevent this

(automatic dishwashers) too much detergent

from happening, use less detergent if you have soft water.
Wash glassware in the shortest cycle that will get them clean.

Excessive/high level

Valve drain hose pinched,

• Any restriction in this drain hose may prevent proper

of water in brine tank

plugged, elevated too high

operation of the injector and screen and reduce or prevent

or otherwise restricted

brine draw during regeneration.

Injector or injector screen dirty

• See the Cleaning the Injector and Screen section, page 17.

With water pressure to the water softening system off,
remove the injector and injector screen. Thoroughly clean
and flush. Check for any damage. Reassemble to valve
assembly.