Advanced troubleshooting – GE GNPR40L User Manual

Page 24

background image

24

Code

Description

Cause

Solution

Err 1

Electronics failure

Control settings need reprogramming

Press any key to load default values.

Refer to Programming the Control.

Err 2

Improper start of

Valve cam gear has been manually

Press any key to clear the alarm.

regeneration (limit switch

rotated during a regeneration

(Alarm automatically clears at “TIME OF

open when it should be

REGEN”).

closed)

Valve cam gear has been manually

The control will turn the motor on and drive

rotated out of “service” position

the cam gear to the proper location.

Faulty motor

Replace motor assembly.

Motor wire disconnected

Make sure motor wire is fully connected to

control.

Faulty switch

Replace switch.

Err 3

Improper finish of

Valve cam gear has been manually

The control will turn the motor on and

regeneration (limit switch

rotated out of “service” position

drive the cam gear to the proper location.

closed when it should be open)

Faulty motor

Replace motor assembly.

Motor wire disconnected

Make sure motor wire is fully connected to

control.

Faulty switch

Replace switch.

Err 4

Improper control settings

One or more settings is out of the

See the Advanced Programming

(one or more settings out

allowable range

Parameters section on page 22 and Default

of the allowable range)

Settings section on page 23.

Manual Indexing for Each Regeneration

The control valve may be manually indexed to each
regeneration position as follows:

1. Remove the control valve cover.

2. Press down on the top of the drive gear to disengage the

cam gear. (See Step 1 in Start-Up Rinsing Procedure
section.)

3. With the cam gear disengaged, rotate the cam gear

counterclockwise to the various positions, using the same
steps as the Start-Up Rinsing Procedure.

The control valve may also be operated in a fast mode for
testing the control. To activate the fast mode, follow Steps 1
and 2 above to disengage the cam gear. When the cam
gear is disengaged, it should be advanced slightly in a
counterclockwise direction.

The switch will then activate the motor to cause the cam gear
to advance through all the cycles in about 30 minutes. The
control will not recognize a fast mode as a regeneration.
Manual regenerations can be initiated only by pressing the
manual regeneration switch on the face of the control.

Errors

This system continuously monitors itself and displays an error
message if it detects something wrong.

When an error is detected, the display shows the letters “Err”
with a number from 1 to 4. The table below lists Err numbers,
a description of each error, the cause of the error and the
solutions.

To clear the error from the display, press any button on the
control. If the error still exists, the control will display the error
message again after 30 seconds.

Advanced troubleshooting.

Error Detection Codes

This manual is related to the following products: