The following table represents preset values programmed into
the system at the factory for both levels for the model shown.
Required Parameters
Name
Description
GNPR40L
GNPR48L
P1
Time of day
Set in field
Set in field
P2
Time of regeneration
2:00 a.m.
2:00 a.m.
P3
Hardness
Set in field (25 grains)
Set in field (25 grains)
P4
Salt amount
7.5 lbs
9.0 lbs
P5
Capacity
24.4 Kgr
26.1 Kgr
Advanced Programming Parameters
Name
Description
GNPR40L
GNPR48L
P6
Refill controller
0.33 gpm
0.33 gpm
P7
Brine draw value
15 min.
16 min.
P8
Not used
N/A
N/A
P9
Backwash time
12 min.
12 min.
P10
Slow rinse time
67 min.
83 min.
P11
Fast rinse time
4.0 min.
4.0 min.
P12
Units of measure
0
0
P13
Clock mode
0
0
P14
Calendar override
0
0
P15
Reserve type
0
0
P16
Fixed reserve capacity
N/A
N/A
or initial average value
P17
Operation type
1
1
P18
Salt/capacity change
0
0
lock out
P19
Factory defaults
9
9
Default Settings