The coil with the outside air flowing over it should be inspected
annually and cleaned as frequently as necessary to keep the
finned areas free of lint, hair and debris.

C

ONDENSER

, E

VAPORATOR

,

AND

I

NDUCED

D

RAFT

M

OTORS

Bearings on the air circulating blower motor, condenser mo-
tor and the combustion fan motor are permanently lubricated.
No additional oiling is required.

L

UBRICATION

The fan shaft bearings, the 1 to 2 HP supply fan motors the
condenser fan motors and compressors are permanently lu-
bricated.

F

UNCTIONAL

P

ARTS

Refer to the unit Parts Catalog for a list of functional parts.
Parts are available from your distributor.

SERVICE

WARNING

HIGH VOLTAGE!

INSTALLATION

AND

REPAIR

OF

THIS

UNIT

SHOULD

BE

PERFORMED

ONLY

BY

INDIVIDUALS

MEETING

THE

REQUIREMENTS

OF

AN

“E

NTRY

L

EVEL

T

ECHNICIAN

AS

SPECIFIED

BY

THE

A

IR

C

ONDITIONING

AND

R

EFRIGERATION

I

NSTITUTE

(ARI). A

TTEMPTING

TO

INSTALL

OR

REPAIR

THIS

UNIT

WITHOUT

SUCH

BACKGROUND

MAY

RESULT

IN

PRODUCT

DAMAGE

,

PERSONAL

INJURY

OR

DEATH

.

THE FOLLOWING INFORMATION IS FOR USE BY QUALI-
FIED SERVICE AGENCY ONLY: OTHERS SHOULD NOT
ATTEMPT TO SERVICE THIS EQUIPMENT.

Common Causes of Unsatisfactory Operation of Heat Pump
on the Heating Cycle.

I

NADEQUATE

A

IR

V

OLUME

T

HROUGH

I

NDOOR

C

OIL

When a heat pump is in the heating cycle, the indoor coil is
functioning as a condenser. The return air filter must always
be clean, and sufficient air volume must pass through the
indoor coil to prevent excessive discharge pressure, and high
pressure cut out.

O

UTSIDE

A

IR

INTO

R

ETURN

D

UCT

Do not introduce cold outside air into the return duct of a heat
pump installation. Do not allow air entering the indoor coil to
drop below 65° F. Air below this temperature will cause low
discharge pressure, thus low suction pressure, and exces-
sive defrost cycling resulting in low heating output. It may
also cause false defrosting.

U

NDERCHARGE

An undercharged heat pump on the heating cycle will cause
low discharge pressure resulting in low suction pressure and
frost accumulation on the outdoor coil.

P

OOR

“T

ERMINATING

” S

ENSOR

CONTACT

The unit’s defrost terminating sensor must make good ther-
mal contact with the outdoor coil tubing. Poor contact may
not terminate the unit’s defrost cycle quickly enough to pre-
vent the unit from cutting out on high discharge pressure.