beautypg.com

Step 2, install the rangetop, Step 3, connect rangetop to gas, Installation – GE Monogram Professional Rangetop User Manual

Page 10: Warning

background image

10

Installation

INSTALL RANGETOP

•Slide the rangetop into the opening. Make sure

the rangetop is evenly seated and supported.

•A hold-down strap with screws is provided to

secure the rangetop to the rear or side cabinet
walls.

•Remove the hold-down strap from the back

of the rangetop. Attach one end of the strap
to the back of the rangetop.

•Secure the other end of the strap as high as

possible to the cabinet back wall or adjacent
cabinet. Keep the strap as short as possible for
better security.

STEP 2

CONNECT RANGETOP TO GAS

WARNING

Do not use a flame to check for gas leaks.

A manual shut-off valve must be installed where
it will be accessible.

Assure that gas is turned off at the shut-off
valve.

•Install the supplied pressure regulator onto the end

of the gas inlet.

•You can install a 90° elbow (not provided) onto the

gas inlet and route the gas connections to avoid
interference with drawers or other cabinetry
features. However, it is not recommended because
it will result in a drop in gas pressure.

•Make sure the regulator is installed in the right

direction. See arrow on the underside of the
regulator.

NOTE: Instead of using solid piping to connect
to pressure regulator, an approved flexible metal
appliance connector may be used between the pipe
stub and the shut-off valve to the pressure regulator,
if local codes permit.

•Turn on gas and check for leaks:

–Use a liquid leak detector at all joints and

connections in the system.

IMPORTANT: Disconnect the rangetop and the
individual shut-off valve from the gas supply piping
system during any pressure testing of that system
at test pressures greater than 1/2 psig. Isolate
the rangetop from the gas supply piping system
by closing the individual manual shut-off valve
to the rangetop during any pressure testing
of the gas supply piping system at test pressures
equal to or less than 1/2 psig.

STEP 3

Regulator
(Supplied)

Note: Pipe stub extends
about 1” below burner
box.

Solid Piping
or Flexible
Connector

Shut-Off
Valve

Pipe Stub From
House Gas Supply

Rangetop Burner Box

1/2” N.P.T.
Gas Inlet

Back Wall

Hold-Down
Strap
Location and
Attachment