– GE Monogram 36" dual Fuel professional Range with

4 Burners and Griddle

dimensions and Clearances (in inches)

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

GEAppliances.com or call GE Answer Center

®

service, 800.626.2000.

specification Revised 3/08

130542

Listed by

Underwriters

Laboratories

Professional ranges offer a number of choices in size and cooktop

configurations.
All Professional Ranges are factory set for natural or liquid propane

gas. The correct model should be ordered for the installation situation.
36" natural Gas Model

ZDP36N4DHSS–4 gas burners and griddle

36" liquid propane Gas Model

ZDP36L4DHSS–4 gas burners and griddle
note: Conversion kits (WB49X10132, Natural to LP and WB49X10133,

LP to Natural) are available if the wrong gas type was ordered. High

Altitude kit, WB49X10130 (for Natural and LP gas models), is also

available. The kits must be installed by a qualified service technician

at additional cost.
Installation Information

Before installing, consult installation instructions packed with product

or online at Monogram.com for current dimensional data.
A 36" or 42" wide professional vent hood with a minimum 600 CFM

is recommended for installation over this range.

Advance planning

Refer to dimensional drawings for appropriate placement and

necessary clearances when planning the installation.
• Cabinetry cannot be installed directly above the range.
• Working areas adjacent to the range should have 18" minimum

clearance between countertop and cabinet bottom.

• Clearance between range and side wall or combustible material

must be at least 12" on each side.

If the range is installed in an island
• Allow 12" minimum clearance at the back to combustible materials.
• The vent hood blower should provide at least 600 CFM and up to

1200 CFM.

• Installation must conform with local codes. In the absence of local

codes, the range must comply with the National Fuel Gas Code,

ANSI Z223.1-1990.

Clearances between range and side wall or combustible material must

be at least 12" on each side.

22"

1-1/2"

35-1/4"

to

36-3/4"

28-1/4"

35-7/8"

Optional

Backsplash

12"