24

Limit Nut

B

Closed position stop –

if gate opens right to left.

Open position stop –

if gate opens left to right.

Limit Nut A

Open position stop –

if gate opens right to left.

Closed position stop –

if gate opens left to right.

After the operator is installed, adjust the open and

closed position limit switches as needed. The limit

switches determine how far the gate travels to open

and to close.

Adjust the limit switches using the limit nuts. Lift limit

switch plate to adjust limit nuts (see Illustration M).

The open and closed position switches will be reversed

depending on whether the gate opens from left to right

or from right to left (see Illustration N).

WARNING! In order to adjust switches, the

control box must be ON. USE EXTREME

CAUTION when adjusting limit switches

to prevent fingers, hair, clothing, etc., from

getting caught under the limit switch plate and

possibly causing bodily injury.

A

DJUSTING

T

HE

L

IMIT

S

WITCHES

Illustration M

Illustration N

Limit Nut B

Limit Nut A

Limit Switch Plate

Motor

However, if your gate opens from Left to Right:

1. Gate Opening: For gate to open further, turn Limit

Nut B counterclockwise. For gate to open less, turn

Limit Nut B clockwise.

2. Gate Closing: For gate to close further, turn Limit

Nut A counterclockwise. For gate to close less, turn

Limit Nut A clockwise.

Once the limit switches are adjusted, make sure the limit

switch plate rests in the grooves on both limit nuts.

If your gate opens from Right to Left:

1. Gate Opening: For gate to open further, turn Limit

Nut A counterclockwise. For gate to open less,

turn Limit Nut A clockwise.

2. Gate Closing: For gate to close further, turn Limit

Nut B counterclockwise. For gate to close less,

turn Limit Nut B clockwise.

Clockwise

Counter Clockwise

This manual is related to the following products: