beautypg.com

Installation instructions, Warning – GE GXFM07HBL User Manual

Page 6

background image

6

LIMITED ONE-YEAR WARRANTY

What does this warranty cover?

– Any defect in materials or workmanship in the manufactured product

What does this warranty not cover?

– Filter Cartridges
– Service trips to your home to teach you how to use the product
– Improper installation
– Failure of the product if it is abused, misused, altered or used for other than

the intended purpose

– Defects that result from improper installation or damage not caused by GE
– Liability on the part of GE under this or any other warranty for any indirect

or consequential damage

– Products that are used for commercial or industrial applications
– Use of this product where water is microbiologically unsafe or of unknown quality,

without adequate disinfection before or after the system. Systems certified for cyst
reduction may be used on disinfected water that may contain filterable cysts.

– Damage to the product caused by accident, fire, floods or acts of God
Incidental or consequential damage caused by possible defects with

this appliance, its installation or repair

For how long after the original purchase?

– One Year

How do I make a warranty claim?

– Return to the retailer from which it was purchased along with a copy

of the “Proof of Purchase.” This warranty excludes the cost of shipping
or service calls to your home.

How does state law relate to this warranty?

– This warranty gives you specific legal rights, and you may also have other rights

which vary from state to state. THIS WARRANTY IS INTENDED TO BE IN LIEU
OF ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Contact us at GEAppliances.com, or call 800.GE.CARES (U.S.), or toll-free 866.777.7627
(Canada).

Installation Instructions

PERFORMANCE DATA
GE GXFM07HBL AND GXFM07HWW WITH
FXMLH CARTRIDGE FAUCET MOUNT FILTRATION SYSTEM

This system has been tested according to NSF/ANSI 42 and 53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.

Average Max.

Permissible

Influent Challenge

Product Water

Reduction

Minimum

Average

Substance

Concentration

Concentration

Requirements

Reduction

Reduction

Standard 42
Aesthetic Chlorine

1.94 mg/L

≥ 50%

97.4%

Particulates

11,666,667 particles/mL

≥ 85%

99.9%

(0.5 to < 1

∝m)

Class I
Standard 53
Cysts

2)

170,000/L

99.95%

99.99%

99.99%

Lead (6.5 pH)

0.14 mg/L

0.010 mg/L

99.3%

99.3%

Lead (8.5 pH)

0.15 mg/L

0.010 mg/L

99.3%

99.3%

Lindane

0.002 mg/L

0.0002 mg/L

98.0%

99.0%

Mercury (6.5 pH)

0.006 mg/L

0.002 mg/L

96.6%

96.6%

Mercury (8.5 pH)

0.005 mg/L

0.002 mg/L

77.4%

89.7%

Benzene

0.015 mg/L

0.005 mg/L

96.6%

96.6%

Carbofuran

0.08 mg/L

0.04 mg/L

97.6%

98.7%

P-Dichlorobenzene

0.225 mg/L

0.075 mg/L

99.8%

99.8%

Toxaphene

0.015 mg/L

0.003 mg/L

93.2%

93.2%

2) Based on the use of live cysts.
Testing was performed under standard laboratory conditions; actual performance may vary.
NOTE: Substances reduced are not necessarily in your water. Filter must be maintained according to manufacturer’s
instructions, including replacement of filter cartridges.

WARNING

Do not use with water that is microbiologically unsafe or of unknown quality without

adequate disinfection before or after the system. Systems certified for cyst reduction may be used on
disinfected waters that contain filterable cysts.
Test Conditions:

Operating Requirements:

• Flow Rate: 0.6 gpm (2.3 Lpm)

• Service Flow Rate: 0.6 gpm (2.3 Lpm)

• Inlet Pressure: 60 psi (4.1 bar)

• Rated Service Life: 75 gallons (284 liters)

• pH of 7.5±1

• Pressure: 30–125 psi (2.1–8.6 bar/kglcm2)

• Temp of 50°–77°F (10°–25°C)

• Temperature: 40°–100°F (4.4°–37.7°C)