Keychain Touchpad Arming

Your installer can set up your keychain touchpad to arm the system in one of two ways:
• Press the

Lock button to arm the system directly to Level 3—AWAY with no Exit Delay.

Using this method, you would not be able to arm to Level 2—STAY.

• Press the

Lock button once for each desired increase in arming level. For example:

From Level 1 press the

Lock button once to arm to Level 2, press it twice for Level 3, or

press it three times to arm to Level 3 with Latchkey activated (if programmed). The Exit

Delay time is applied. For more information, see “Latchkey Paging”.

Note

Your system can be set up to sound short beeps on exterior sirens when arming or disarming the sys-

tem from outside using a keychain or wireless touchpad. This provides confirmation that an arming level

change was successful. Ask your installer about this feature.

Using the Chime Feature

Turning on the Chime feature is like having a doorbell on every protected door and window.

When this feature is on, interior sirens and speakers sound 2 beeps whenever anyone opens a pro-

tected door or window.
The Chime feature works only in Level 1—OFF.

To turn Chime on/off:

1. While in Level 1—OFF, from any touchpad, Press

7

+

1

. While the Chime feature is on,

touchpads display, “CHIME IS ON” or “CHIME ON.”

Chime-On-Close

The Chime-On-Close feature works like the regular Chime feature, but in addition to the double

beeps heard upon opening a protected door or window, the system sounds one long beep when

the door or window is closed again.
You can turn the Chime-On-Close feature on or off from the programming menus. Refer to

“Using Programming Menus” for information on programming your system.

Using the Voice Chime Feature

Your system may have the ability to speak the sensor name whenever someone opens a protected

door or window. When this feature is on, speakers announce, “Sensor name open/closed.” You

can turn the Voice Chime feature on or off from the programming menus. Check with your

dealer and refer to “Using Programming Menus” for information.

No Delay—For Instant Alarm

You can choose to turn off the Entry and Exit Delays, causing the delay doors to arm immedi-

ately. Anyone entering through a delay door when the system is set to No Delay would immedi-

ately cause an alarm.
No Delay is normally used:
• When staying home after arming the system.
• When arming or disarming your system from outside (requires a wireless touchpad).

Note

If Quick Arm feature is on,

an access code is not

required. See the “Quick

Arm” section in this manual.

Arming to Level 2 or 3 with No Delay, using a touchpad:

1. Close all perimeter doors and windows.
2. Enter

2

+

CODE

or

3

+

CODE

. The system sounds two or three short beeps.

3. Immediately press

4

. Touchpads display, “ARMED TO STAY NO DELAY” or “ARMED

TO AWAY NO DELAY”.