Shutdown & Cleaning - After Hopper Method Applications

20

312079A

Shutdown & Cleaning - After Hopper Method
Applications

For short term shutdown periods (overnight to
one week) refer to Short Term Storage, page
29.

For flushing after spraying oil-based coatings,
use compatible oil-based flushing fluid or min-
eral spirits.

For flushing after spraying water-based coat-
ings, use water.

If you are using water-based materials, you
have the option of following the cleanup proce-
dure described below, or for faster cleanup,
Power Flush, starting on page 22.

1. Relieve pressure, page 7.

2. If you used a spray gun, remove tip and guard

assembly from gun and place in flushing fluid.

If you used a roller, leave roller assembly
attached to gun.

3. Pour unused paint out of

hopper and back into original
container.

4. Place drain tube in waste

pail.

5. Use inlet screen handle

to remove inlet screen
from hopper. Place it in a
bucket of clean water or
cleaning solvent.

6. Turn AllControl to

PRIME/CLEAN PUMP to
remove excess paint in
hopper.

7. If you used a liner, carefully remove liner from

hopper and dispose of it in a proper trash
container.

8. Fill a bucket with water or

cleaning solvent and pour it
into hopper.

9. Plug sprayer in grounded outlet.

10. Set AllControl to

PRIME/CLEAN PUMP.
Circulate fluid for at least a
minute.

11. Turn AllControl to OFF.

12.

a. If you used a spray gun

only, continue with Step
11.

b. If you used a roller follow Cleaning Roller

instructions beginning on page 28.

ti9292a

ti9376a

ti9378a

Step 13 is for returning paint in hose back to
paint pail. One 25-ft (7.5 m) hose holds
approximately 1-pint (1.5-liter) of paint.

ti9168a

ti9377a

ti9169a

ti9168a