beautypg.com

GE E4H-CE Series User Manual

Page 33

background image

SYMPTOM

High operating pressure

Water flowing when

machine is turned OFF

Declining rejection (high

permeate conductivity)

POSSIBLE CAUSES

Recycle or concentrate valve

plugged

Inaccurate pressure gauge

Restricted flow after pump

outlet

Telescoped membrane ele-

ment covering membrane ele-

ment housing outlet port

Inlet solenoid valve not clos-

ing or seating properly

Severely fouled or dirty

membrane elements

Dirty or fouled membrane

elements

REMEDIES

Disassemble the plumbing

to the recycle valve and

remove foreign particles.

Check the concentrate

valve stem.

Replace or calibrate the

gauge as required.

Check for blockage of the

concentrate flow at the

inlets and outlets of the

membrane element

housings.

Ensure that the anti-tele-

scoping device (ATD) is

located properly on the

membrane elements.

Clean or replace the valve.

Clean the membrane ele-

ments with detergent

immediately. Water must

not pass through the inlet

when the machine is OFF.

Flush and clean the mem-

brane elements.

28

TROUBLESHOOTING

This manual is related to the following products: