TROUBLESHOOTING

This troubleshooting guide can assist you in identifying common operating problems you may
experience with your machine. The operator can easily correct many of these problems, howev-
er, for those that persist or are not understood you should contact the GE Osmonics Customer
Support Center. Have the following information available when calling the Customer Support
Center:

1. Machine installation date
2. Model number
3. Serial number
4. Detailed description of problem

SYMPTOM

Low operating pressure

POSSIBLE CAUSES

Insufficient feed water pressure

flow

Clogged pre-filter

High flow rates

Dirty or fouled membrane

elements

Solenoid valve not opening

Pump rotating backwards

(three-phase power only)

REMEDIES

Open the feed pressure, open

the feed water valve, and

check for restrictions.

Replace pre-filter cartridge.

Close the concentrate valve,

check the permeate and con-

centrate flow rates and adjust

if necessary. Excessive per-

meate flow may indicate a

damage O-ring.

Flush and clean the membrane

elements.

Clean or replace the solenoid

valve.

Switch any two three-phase

leads to the motor starter.

25

TROUBLESHOOTING