beautypg.com

GE E4H-CE Series User Manual

Page 14

background image

1.4.5

Reverse Osmosis Membrane Element Rejection

E8-CE RO machines use Fiberglass Reinforced Plastic (FRP). E4H-CE RO
machines use tape wrapped membrane elements. For more information, refer to
the Spare Parts List (P/N 1233377).

Table 1.3

Membrane Element

Specifications

9

Specification

Outer Cover Material

Typical Ionic Rejection (TDS)

Nominal Permeate Flow Rate

[at 7.6 bar (110 psi)]

Typical Feed Water

Temperature Range

Maximum Temperature Range

Short-Term Cleaning

Temperature

pH Range

Chlorine Tolerance

Active Membrane Area

Average Molecular Weight

Cutoff*

E4H-CE

Tape

98.0 - 99.5%

8.3 m

3

/d (2200 gpd)

10° - 29°C (50° - 85°F)

0° - 40C (32° - 104°F)

< 43°C (110°F)

3.0 - 11.0

< 0.1 ppm

7.9 m

2

(85 ft

2

)

1500 MW*

E8-CE

FRP

98.0 - 99.5%

39.8 m

3

/d (10500 gpd)

10° - 29°C (50° - 85°F)

0° - 40°C (32° - 104°F)

< 43°C (110°F)

3.0 - 11.0

< 0.1 ppm

32.5 m

2

(350 ft

2

)

1500 MW*

*

The Molecular Weight (MW) cutoff is based on the pore size of membrane elements and the
nature (size/shape) of the organic molecule.

This manual is related to the following products: