beautypg.com

Service, Caution – Graco Inc. 224200 User Manual

Page 23

background image

308131 23

Service

Air Cap/Nozzle/Resistor Stud Replacement
(continued)

6.

Trigger the gun while installing the fluid nozzle (21)
and resistor stud (22) assembly with the multi-tool
(62). Tighten until the fluid nozzle seats in the gun
barrel (1/8 to 1/4 turn past hand tight).

7.

Install air cap assembly (1, 8, 49) and retaining
ring (2). Test gun resistance as instructed on page
20.

05154A

Fig. 11

20

1, 8, 49

21

22

2

25

62

D

Apply a very light coat of
lubricant

Tighten 1/8 to 1/4 turn
past hand tight

0444A

21

22

62

Fig. 12

Torque to 10 in-lbs (1.12 N

S

m)

Electrode Needle Replacement

1.

Prepare the gun for service as instructed on page
22.

2.

Remove the air cap, nozzle and resistor stud as
instructed on page 22.

3.

Unscrew and remove the electrode needle (20)
with the multi-tool (62). Hold the fluid rod end to
prevent it from turning. See Fig. 13.

CAUTION

Be careful not to damage the contact wire when
removing the electrode from the gun.

4.

Apply low-strength (purple) Loctite

r

or equivalent

thread sealant to the electrode needle and fluid rod
threads. Install the electrode needle finger-tight.
Do not over-tighten it.

CAUTION

To avoid damaging the plastic threads or contact
wire, be very careful when installing the electrode.

5.

Install the fluid nozzle, resistor stud, and air cap
assembly as instructed at left.

6.

Test the gun resistance as instructed on page 20.

0378A

Fig. 13

62

20

Apply low-strength (purple) Loctite or equivalent to fluid rod
threads

This manual is related to the following products: