Zoneline, Chassis nomenclature, Receptacles/sub-bases – GE Monogram 5800 Series User Manual

Page 54: Example, Az 5 8 h 1 2 d a d

background image

54

Zoneline

®

Chassis Nomenclature

EXAMPLE

Receptacles/Sub-Bases

RAK204U

RAK204D15P

RAK204D20P

RAK204D30P

RAK204E15

RAK204E20

RAK204E30

Voltage

N/A

20/208

20/208

20/208

265

265

265

Amps

N/A

15

20

0

15

20

0

Receptacle

N/A

NEMA6-20R

NEMA6-20R

NEMA6-0R

NEMA7-15R

NEMA7-20R

NEMA7-0R

20/208-Volt sub-bases include appropriate power cord kit.

265-Volt units are to be direct connected. Cordset through enclosed chaseway into interior sub-base receptacle meets the NEC requirements.

Sub-Bases

Tandem
20/208V 15 Amp
NEMA6-15R

Perpendicular
20/208V 20 Amp
NEMA6-20R

Large tandem
20/208V 0 Amp
NEMA6-0R

265V 15 Amp
NEMA7-15R

265V 20 Amp
NEMA7-20R

265V 30 Amp
NEMA7-0R

LCDI Power Connection Kit

Heater KW

Watts

BTUH
Amps

Min. circuit amps

Recommended

protective

device

*To be used with sub-base

RAK3153

RAK3203

RAK3303

2.55/2.09

.45/2.82

5.00/4.09

2,550/2,090

,450/2,820

5,000/4,090

8,600/7,100

11,700/9,600

17,000/1,900

11.6/10.6

15.6/14.2

22.4/20.4

15

20

0

15-amp

20-amp

0-amp

time-delay

time-delay

time-delay

fuse or breaker

fuse or breaker

fuse or breaker

265-volt Permanent connected units* (Cord set)

RAK5172

RAK5202

RAK5302

2.55

.45

5.0

2,560

,450

5,000

8,600

11,700

17,000

10.

1.8

19.6

15

20

0

15-amp

20-amp

0-amp

time-delay fuse

time-delay fuse

time-delay fuse

230/208-volt

Line cord connected units

Power connection kits are required on all

Zoneline chassis (see chart below).

The correct kit for the installation is determined by the voltage and
amperage of the electrical circuit and the means of connecting the
unit to the building wiring. If the unit is to be plugged into a receptacle,
a line cord kit would be used; if the unit is to be permanently connected,
a permanent connection kit would be used. 265-volt cord set units must
be installed in compliance with National Electrical Code.

Power connection kits

required on all models. See specification sheet

for heater KW and branch circuit ampacity.

RAK15/RAK20/RAK0

20/208-volt line cord

connection kit

RAK4157/RAK4207/RAK407

20/208-volt universal power

supply kit

The Zoneline chassis is identified by a model number defining
the type of unit, cooling capacity, electrical information and
optional features included on the unit. When specifying or
ordering the Zoneline chassis use of this nomenclature will
assure receiving the correct unit.

A

Z

5

8

H

1

2

D

A

D

Chassis series

29= deluxe line cool/

electric heat

9=deluxe line heat pump

58= premium line

heat pump

Unit type

E= cooling with electric

resistance heat

H= heat pump with electric

resistance heat

Zoneline

packaged

terminal

chassis

Nominal cooling capacity

07=7,000 BTUH cooling

09=9,000 BTUH cooling

12=12,000 BTUH cooling

15=15,000 BTUH cooling

Special Features

B=base unit

C=corrosion treated

D= internal

condensate

removal (ICR)

system (heat

pump models

only) (not for

coastal areas)

P=Dry Air 25

Voltage/Phase/

Frequency

D= 20/208 Volt, single

phase, 60 Hz

E= 265 Volt, single phase,

60 Hz

Universal

power connection

Heater KW

Watts

BTUH
Amps

Min. circuit amps

Recommended

protective

device

RAK4157

RAK4207

RAK4307

2.55/2.09

.45/2.82

5.00/4.09

2,550/2,090

,450/2,820

5,000/4,090

8,600/7,100

11,700/9,600

17,000/1,900

11.6/10.6

15.6/14.2

22.4/20.4

15

20

0

15-amp

20-amp

0-amp

time-delay

time-delay

time-delay

fuse or breaker

fuse or breaker

fuse or breaker

265-volt Direct Connection Kit**

RAK5157

RAK5207

RAK5307

2.55

.45

5.0

2,560

,450

5,000

8,600

11,700

17,000

10.

1.8

19.6

15

20

0

15-amp

20-amp

0-amp

time-delay fuse

time-delay fuse

time-delay fuse

230/208-volt

Direct Connection Kit**

**To be used with sub-base or connection to building wiring

RAK5157/RAK5207/RAK507

265-volt universal power

supply kit