Guardian Technologies ACT1000 User Manual
Page 20
![background image](/manuals/107794/20/background.png)
ACT1000/2000 Operating Instructions Software Version 3.23-00
Page 17 of 32
Timers
The door timers menu allows the installer to program the time delays for the relay, AUX
output, open collector outputs OP2 and OP3 and the door ajar alarm time. Each timer may be
programmed with a duration from 1 to 999 seconds
.
The relay time may be programmed to 0
seconds, which will operate the relay for a quarter of a second approximately. This can be
used for turnstile applications. Door Stations will support a maximum duration of 127
seconds.
Timed Actions
This Menu allows the user to set up a number of timed actions that are linked to timezones.
Any combination of up to eight timezones may be assigned to an action. When any one of
these timezones is in force, then the assigned action occurs for that duration
.
Action
What Happens.
Unlock Door
For the duration of the assigned timezone, the door remains unlocked.
The Green LED on the Reader will Flash
Lock Door
For the duration of the assigned timezone, the door remains locked.
The Red LED on the Reader will Flash.
PIN Required
For the duration of the assigned timezone, a valid PIN code must be
entered after any card is presented. This overrides any PIN required
option that may be set for any group or user.
Any Card
For the duration of the assigned timezone, any card presented will be
granted access as long as it contains Track 2 data, even if it would not
normally be granted access.
Activate OP2
For the duration of the programmed timezone, the user programmable
output OP2 is active.
Activate OP3
For the duration of the programmed timezone, the user programmable
output OP3 is active.
Activate AUX
For the duration of the programmed timezone, the 1A auxiliary relay
output AUX is active.
PIN Only
For the duration of the programmed timezone, the reader is disabled,
and access is granted only by entering a valid PIN.
PIN or Card
For the duration of the programmed timezone, either a valid PIN or a
valid Card will allow access.
Communications
This menu allows the installer to configure how the controller communicates with externally
connected devices or over a network. It is used primarily to configure the communications
mode or address of the unit, or to specify log printer options.
Set Address
This option allows the address of the controller to be set when it is operating in a networked
system or when directly connected to a PC. The valid address may be from 1 to 255 and
corresponds to the number of the controller as configured in ACTWinPro.
Direct Conn.
This option informs the controller that it is connected directly to a controlling PC, rather than
via a network interface. In this mode of operation, only a single controller may be connected
to the PC via a cable (max 30m) from one of the PC serial ports.