beautypg.com

Guardian Technologies ACT1000 User Manual

Page 17

background image

ACT1000/2000 Operating Instructions Software Version 3.23-00

Page 14 of 32

System Settings

The System Settings menu allows the installer to access a number of different configuration
menus controlling different aspects of the setup of the controller. Pressing the ✔

✔ key toggles

the setting of a displayed option.

Operation

This menu allows the installer to select or de-select a number of options relating to the
default operation of the controller.

The PIN Only option allows reader-less operation using PIN codes that are directly
entered on the keyboard (or on an external keypad). Up to 2000 codes may be used.

The Learn option allows the first 2000 users to use randomly coded cards. Almost any
card with valid ISO track 2 data may be used (for example bankcards) as well as some
types of wiegand card.

The Ext. Keypad option allows an external ACT20 keypad to be used for PIN entry on an
ACT1000 controller. By default, the ACT1000’s own keypad is used.

The KPD Release option allows the ✔

✔ key on an ACT1000 to function as an exit switch.

The Exit PIN’s option is applicable for ACT1000 PIN-only systems. When set, it requires
PIN codes to be entered before the user is allowed to exit.

The Second Door option allows an auxiliary door to be controlled on an ACT1000 unit.

The User Limiting option will prevent access to tracked users when the user limit is
reached.

The One-To-One option allows any card number to be assigned to any of the first
1000/2000 users.

The Multiple option allows users to have more than one card on the system.

Display

The Backlight option forces the keypad to be permanently illuminated, overriding the
default automatic operation, which is to operate only when a user menu has been entered.

Keypad Beep option forces the keypad to make a short beep in response to any key being
pressed. This option is selected by default.

The Show Status option enables the displaying of continuous door status on the display.
This option is enabled by default.

The Show Events option enables the displaying of events on the display as they occur.
This option is enabled by default.

The Handshake option is used when a serial printer is connected. When selected,
information will only be sent to the printer when a positive signal is applied to the RX pin
on the printer port. This may be used to temporarily halt printing when the printer is
disconnected or out of paper.

The Tech Bleep option specifies that the ACT2000’s onboard buzzer will sound
intermittently if a technical fault (mains, tamper or door offline) condition exists.


PIN Length

The length of PIN codes used in PIN Only and PIN & Card modes may be set between 4 and
9 digits. If a PIN length greater than six is set, then the length of the operator and installer
codes will increase to this length. (Leading zeros added to PIN).