7 prompt, 1 changing the command line prompt, Prompt -15 – GE MULTILINK ML2400 User Manual
Page 287: Hanging, Ommand, Rompt

CHAPTER 17: MISCELLANEOUS COMMANDS
MISCELLANEOUS COMMANDS
MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
17–15
17.7 Prompt
17.7.1 Changing the Command Line Prompt
Setting a meaningful host prompt can be useful when a network administrator is
managing multiple switches and has multiple telnet or console sessions. To facilitate this,
the ML2400 allows administrators to define custom prompts. The command to set a
prompt is:
set prompt
The length of the prompt is limited to 60 characters.
There are predefined variables that can be used to set the prompt. These are:
• $n: system name
• $c: system contact
• $l: system location
• $i: system IP address
• $m: system MAC address
• $v: version
• $$: the “$” (dollar sign) character
• $r: new line
• $b: space
A few examples on how the system prompt can be setup are shown below.
ML2400#
snmp
ML2400(snmp)##
setvar sysname=Core
System variable(s) set successfully
ML2400(snmp)##
exit
ML2400#
set prompt $n
Core#
set prompt $n$b$i
Core 192.168.5.5#
set prompt $n$b$i$b
Core 192.168.5.5 #
snmp
Core 192.168.5.5 (snmp)##
setvar sysname=ML2400
System variable(s) set successfully
Core 192.168.5.5 (snmp)##
exit
Core 192.168.5.5 #
set prompt $b$b$i$b
192.168.5.5 #
set prompt $n$b$i$b
ML2400 192.168.5.5 #
ML2400 192.168.5.5 #
set prompt Some$bthing$i
Some thing192.168.5.5#
set prompt Some$bthing$b$i
Some thing 192.168.5.5#