Pre-operation inspection – Genie AWP 114002 User Manual
Page 13

Operator’s Manual
Third Edition • Fourth Printing
Part No. 114002
Genie AWP Super Series
11
PRE-OPERATION INSPECTION
Pre-operation Inspection
R
Be sure that the operator’s, safety and
responsibilities manuals are complete, legible
and in the storage container located on the
platform.
R
Be sure that all decals are legible and in place.
See Decals section.
R
Check for battery fluid leaks and proper fluid
level. Add distilled water if needed. See
Maintenance section.
R
AC & DC models: Check for hydraulic oil leaks
and proper oil level. Add oil if needed. See
Maintenance section.
R
RT base models: Check for proper tire pressure.
Add air to tires if needed. See Maintenance
section.
R
Air models: Check the oil level of the airline
lubricator. See Maintenance section.
R
Air models: Check the oil lubricator canister drip
rate. Adjust as needed. See Maintenance
section.
R
Air models: Check the air filter/regulator
canister. Drain water as needed. See
Maintenance section.
Check the following components or areas for
damage, improperly installed or missing parts and
unauthorized modifications:
R
Electrical components, wiring and
electrical cables
R
AC & DC models: Hydraulic power unit,
hoses, fittings and cylinder
R
Air models: Air power unit, air lines, fittings
and cylinder
R
Platform entry mid-rail or gate
R
Sequencing cables and pulleys
R
Lifting chains and idler wheels
R
Nuts, bolts and other fasteners
R
Mast columns and counterweight
R
Breather cap
R
Outriggers, leveling jacks and footpads
R
Adjustable glide pads
Check entire machine for:
R
Dents or damage
R
Corrosion or oxidation
R
Cracks in welds or structural components
R
Inspect and clean battery terminals and all
battery cable connections.
R
Be sure that all structural and other critical
components are present and all associated
fasteners and pins are in place and properly
tightened.