beautypg.com

Furuno FR-8122 User Manual

Page 17

background image

1. MOUNTING

1-9

5. Fasten the shielded part of the signal cable with shield clamp (installation material) as

shown below.

Shield clamp

Signal cable

Fix shield wire with bolt.

Gasket support

Cable Entry

How to fix signal cable in cable gland

6. Unfasten four screws to remove the RTB board cover.
7. Connect the plugs of the signal cable to the RTB board.

FR-8062, FR-8122: J821, J823, J824, J822

FR-8252:

J821, J823, J824, J820

RTB board

J820

J823

J822

J824

J821

Connecting to the RTB board

8. Reattach the RTB board cover.