SP - 3

5. POWER SUPPLY

(1) Rated Voltage/Current

12-24 VDC: 5.0-2.5 A

(2) Rectifier (option)

100/110/115/200/220/230 VAC, 1 phase, 50/60 Hz

6. ENVIRONMENTAL CONDITION

(1) Ambient Temperature

Scanner Unit: -25

°

C to +70

°

C

(IEC 60945)

Display Unit: -15

°

C to +55

°

C

(2) Relative Humidity

93 %

±

2% at +40

°

C

(3) Waterproofing

Scanner Unit: IPX6

(IEC 60529)

Display Unit: IPX5

(4) Bearing Vibration

IEC 60945

7. COATING COLOR

(1) Display Unit

Panel: N3.0, Chassis: 2.5GY5/1.5

(2) Scanner Unit

N9.5 (upper), 2.5PB3.5/10 (lower)

8. COMPASS SAFE DISTANCE

(1) Display Unit

Standard: 0.70 m

Steering: 0.50 m

(2) Scanner Unit

Standard: 1.00 m

Steering: 0.75 m