Output
a) Rotate the [ENTER] knob to choose appropriate option and then push the [ENTER]
knob.
Off
On
b) Rotate the [ENTER] knob to choose Off or On as appropriate and then push the
[ENTER] knob followed by
◄.
6. Repeat step 5 to set up other ports.
7. Press the [MENU] key to close all open windows and erase the menu bar.
I/O format
Port I/O
format
Data
sentence
Remarks
NMEA 1,
NMEA 2
IEC-61162-1,
NMEA-0183
Ver. 1.5/2.0/3.0
See table below.
Input
PC/NMEA IN
RS232, and IEC
and NMEA above
For NMEA IN, see
table below.
NMEA 1,
NMEA 2
IEC-61162-1,
NMEA-0183
Ver. 1.5/2.0/3.0
GLL, VTG, BWR, DBT,
DPT, MTW, VHW,
WCV, APA, APB,
HDG, BOD, XTE,
RMA, RMB, RMC,
GGA, HSC, WPL,
RTE, TLL, AAM, GTD,
MWV, ZDA
BWR: Rhumb line
Output
PC/NMEA IN
RS232
Input data, sentence priority
Data
Sentence priority order
Remarks
Speed thru water
VHW
True heading
HDT, HDG, HDM
Magnetic heading
HDT, HDG, HDM
Target position
TLL
Radiotelephone target
position
DSC
Waypoint data
RMB
Depth DPT,
DBT
Water temperature
MTW
Wind current, speed
MWV