5 troubleshooting – Furuno FE-700 User Manual
Page 30

20
6.5 Troubleshooting
The table below provides simple troubleshooting procedures which you may follow to restore normal
operation. If you cannot restore normal operation, contact your dealer.
SYMPTOM PROBABLE
CAUSES
REMEDY
Low power supply
Check the supply voltage.
Fuse blown
Replace the fuse.
No picture; no reading
measure
Power cable damaged
Check the cable and repair.
Transducer cable damaged
Repair the cable.
Transducer cable connection
loosened
Tighten the connections.
No echo sounding picture
Transmitter not working
Make sure the maximum output power is
selected. (See section 3.2 System Menu 1.)
Low sensitivity
Increase the Gain by turning the GAIN control
clockwise.
Low reflectivity from seabed
Suspect muddy seabed.
Irregular display
Marine life on transducer
Remove marine life from the transducer when
dry docked.
Out of range
Check the range scale setting.
Loss of seabed display
Air bubbles caused by going
astern or running over other
ship wakes
This is normal, it is not a sign of equipment
trouble.
Wrong installation place of
transducer
Find cause of noise. Relocate the transducer if
noise persists.
Heavy noise
Other echo sounders nearby
If more than one echo sounder is working on
the ship, there is no ideal measure to cure the
problem.
Aeration in near surface area
Not an equipment problem.
Surface noise
Rough weather
Not an equipment problem.