2 system menu 1, 3 system menu 2 – Furuno FE-700 User Manual
Page 22
12
3.2 System Menu 1
DEPTH UNIT: Selects unit of depth
measurement among meters, feet, or fathoms.
Default setting is meters.
If "ft" or "fa" is selected, the depth unit is shown
in red characters.
SPEED UNIT: Selects unit of speed
measurement among knots, statute miles per
hour, or kilometers per hour. Default setting is
knots. Requires speed data, from external
device.
COURSE: Selects heading reference; true or
magnetic. Default setting is TRUE.
BOTTOM LOST: Turns on or off the bottom loss
warning. “ALARM” sounds the alarm if the
bottom signal is not detected. Default setting is
“ALARM” (alarm is enabled).
GPS ALARM: The audible alarm may be
released when the position-fixing mode is
switched from DGPS to GPS and vice versa.
Default setting is “ALARM” (alarm is enabled).
Choose “OFF” if you do not need to be alerted
with the audible alarm when the position-fixing
mode is switched.
INTERFACE: Selects I/O signal format between
the FE-700 and external equipment; IEC format
“1:95” (1995 version) or “1:98” (1998 version), or
NMEA format. Default setting is IEC “1:98”.
When selecting the “1:98”, DPT has max. range
in use (See page 24).
Output Input
IEC 61162-1
DPT
RMA, RMC
GLL, VTG
ZDA, GGA
NMEA 0183
DBT (Ver.1.5)
DBS (Ver.1.5)
DPT (Ver.2.0)
RMA, RMC
GLL, VTG
ZDA, GGA
ALARM SOUND: Selects audio alarm sound
among 1, 2 or 3. Default setting is 1.
1: Continuous sound
2: Intermittent sound; 0.5 s on and 0.5 s off.
3: Intermittent sound; 1 s on and 1 s off.
OS DATA: Selects own ship data display mode;
DATA 1 or DATA 2. DATA1 is the default setting.
If a navigation device is not connected to the
FE-700, select DATA 2.
LANGUAGE: Currently English is only available.
3.3 System Menu 2
TIME ADJUST: Selects internal clock or external
clock (UTC clock). Default setting is INTERNAL.
For INTERNAL, set current day, month, year,
hour, minute and second with [+], [-], [▼] or [▲]
key. The setting clock appears and it counts
upward.
SYSTEM MENU 2
MENU SELECT 1 2 3
TIME ADJUST
INTERNAL EXTERNAL
DAY
1
MONTH
JAN
YEAR
2001 (
∼
2100)
HOUR
0 (0
∼
23)
MINUTE
0 (0
∼
59)
SECOND
0 (0
∼
59)
01 JAN 2001 00:00:00
▼▲: To select item
- +: To set option
Select other mode to exit.
If EXTERNAL is selected, the screen changes
as follows.
SYSTEM MENU 2
MENU SELECT 1 2 3
TIME ADJUST
INTERNAL EXTERNAL
TIME DIFFERENCE AUTO MANUAL
0:22:40
▼▲: To select item
- +: To set option
Select other mode to exit.
TIME DIFFERENCE: Selects auto (UTC) or
manual. Auto uses the time difference in ZDA
(IEC 61162-1). In manual, it is necessary to
enter the time difference in hours and minutes.