1 basic operation, 123 m, 128 m – Furuno FE-700 User Manual
Page 26
![background image](/manuals/104126/26/background.png)
16
5 OPERATION OF DIGITAL DEPTH
INDICATOR FE-720 (OPTION)
MENU
ENT
DISP
DIM
PWR
*
Omnipad
The Digital Depth Indicator FE-720 is an optional
remote display. The panel illumination can be
locally adjusted on the control panel or on the
optional hand dimmer box.
5.1 Basic Operation
5.1.1 Turning on
Press the POWER key. The unit beeps and starts
up with the last-used display. To turn off the unit,
press the POWER key again.
5.1.2 Adjusting panel dimmer
1.
Press the DIM key.
2.
Press [ ] to increase the dimmer or [ ] to
decrease it. The default is level 4.
3.
Press the ENT key to finish the adjustment.
5.1.3 Adjusting Contrast
1.
Press the [
∗
] key. The following window
appears.
CONTRAST (0-63)
48
EXIT: [ENT]
2.
Press [ ] or [ ] until the required value is
reached. The range of adjustment is from
0 (Min.) to 63 (Max.). The default is 48.
3.
Press the ENT key to set.
Note: The contrast is automatically set to the
default when you turn on the power.
5.1.4 DEPTH MODE
Depths are read either below transducer (keel) or
below seaface irrespective of the main display.
Select the mode as below:
1. Press the DISP key to select the wanted
mode. The mode changes as below with
each press.
DEPTH FORE 50kHz
123 m
BELOW TRANSDUCER
Depth below transducer
DEPTH FORE 50kHz
128 m
BELOW SURFACE*
DRAFT: 5.0 m
Depth below surface. Draft is
determined on the main Display Unit
FE-701.
*: If the draft setting is –10.0 to -0.1 (refer to
page 8.) BELOW KEEL is displayed