beautypg.com

Furuno 2127 User Manual

Page 37

background image

2. WIRING

2-13

J104

J103

J106

J105

J101

PWR board

(P)HV

AC FIL

P108/J108

R21
(OVER)

8 7 6 5 4 3 2 1

Jumper connector
(VH8P)

How to adjust the overvoltage detection circuit:
1. Add or remove the jumper connector P108 and change the fuse.
2. Rotate R21 fully clockwise on the PWR board.
3. Connect a variable transformer between ship's mains and the input power terminal board

TB-1 of the processor unit.

4. Adjust the variable transformer output (i.e., input voltage to the processor unit) as follows.
For 100 VAC set: 144 VAC
For 220 VAC set: 288 VAC
5. Turn on the radar and rotate the R21 counterclockwise gradually until the overvoltage

detection circuit functions (i.e., power supply cuts off).

6. Lower the output voltage of the variable transformer and confirm that the radar

automatically turn on with a voltage lower than 142VAC or 284VAC.

7. Gradually increase the output voltage of the variable transformer and confirm that the

overvoltage detection circuit functions at 144V or 288VAC of the variable transformer
output.

8. Assemble and connect the processor unit.

This manual is related to the following products: