beautypg.com

Alert items – FUJITSU MAF3364LP User Manual

Page 9

background image

viii

C141-E064-03EN

Important

Alert Items

Important Alert Messages

The important alert messages in this manual are as follows:

A hazarous situation could result in minor or moderate personal injury if
the user does not perform the procedure correctly. This alert signal also
indicates that damages to the produt or other property, may occur if the
user does not perform the procedure correctly.

Task

Alert message

Page

Mounting Installation

Heat
An air flow with an adequate wind velocity must be maintained
to deal with much heat generated from the MAF3364xx.
Reference value: An air flow with a wind velocity of more than

0.5 m/s is required in an environment at 40°C,
and an air flow with a wind velocity of more
than 1.0m/s in an environment at 45°C (Center
of DE cover 55°C).

Data loss
1. The user must not change the setting of terminals not

described in this section. Do not change setting status set at
factory shipment.

2. Do not change the setting of terminals except following

setting pins during the power is turned on.

Write protect: CN2 9-10

3. To short the setting terminal, use the short plug attached

when the device is shipped from the factory.

Damage
1. Check that system power is off before connecting or

disconnecting cables.

2. Do not connect or disconnect cables when power is on.

Data loss
When the SEND DIAGNOSTIC command terminates with the
CHECK CONDITION status, the INIT must collect the error
information using the REQUEST SENSE command. The
RECEIVE DIAGNOSTIC RESULTS command cannot read out
the error information detected in the self-diagnostics.

Damage
Do not open the DE in the field because it is completely sealed
.

Data loss
Save data stored on the disk drive before requesting repair.
Fujitsu does not assume responsibility if data is destroyed
during servicing or repair.

4-10

5-5

5-11

6-4

6-5

6-6