2 - 6

(3)

Service life

The service life under suitable conditions and treatment is as follows.

The service life is depending on the environment temperature. Therefore, the user must design
the system cabinet so that the average DE surface temperature is as possible as low.

DE surface temperature: 40°C or less

5 years

DE surface temperature: 45°C or less

4.5 years

DE surface temperature: 46°C to 50°C

4 years

DE surface temperature: 51°C to 55°C

3.5 years

DE surface temperature: 56°C and more strengthen cooling power so that DE

surface temperature is 55°C or less.

Even if the IDD is used intermittently, the longest service life is 5 years.

Note:

The "average DE surface temperature" means the average temperature at the DE surface
throughout the year when the IDD is operating.

(4)

Data security at power failure

Integrity of the data on the disk is guaranteed against all forms of DC power failure except on
blocks where a write operation is being performed. The above does not applied to formatting
disks or assigning alternate blocks.