4 - 10

(3)

Environmental temperature

Temperature condition at installed in a cabinet is indicated with ambient temperature measured
3 cm from the disk drive. At designing the system cabinet, consider following points.

Make a suitable air flow so that the DE surface temperature does not exceed 55°C.

CAUTION

Heat
An air flow with an adequate wind velocity must be maintained to
deal with much heat generated from the MAF3364xx.
Reference value: An air flow with a wind velocity of more than

0.5 m/s is required in an environment at 40°C,
and an air flow with a wind velocity of more
than 1.0m/s in an environment at 45°C (Center
of DE cover 55°C).

Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling
effect by measuring temperature of specific ICs and the DE. These measurement results
should be within a criteria listed in Table 4.1.

Table 4.1

Surface temperature check point

No.

Measurement point

Criteria

1

Center of DE cover

55°C

2

Read channel LSI

83°C

3

VCM/SPM Driver

75°C

4

HDC

85°C

Figure 4.10 Surface temperature measurement points (MAF series, MAE series, MAG series)