6 - 6

Note:

The "average DE surface temperature" means the average temperature at the DE surface
throughout the year when the IDD is operating.

(3)

Parts that can be replaced in the field

The PCA cannot be replaced in the field. The DE cannot be replaced in the field.

(4)

Service system and repairs

Fujitsu has the service system and repair facility for the disk drive. Contact Fujitsu
representative to submit information for replacing or repairing the disk drive. Generally, the
following information must be included:

a) IDD model, part number (P/N), revision number, serial number (S/N), and date of

manufacturing

b) Error status

Date when the error occurred

System configuration

Environmental conditions (temperature, humidity, and voltage)

c) Error history

d) Error contents

Outline of inconvenience

Issued commands and specified parameters

Sense data

Other error analysis information

CAUTION

Data loss
Save data stored on the disk drive before requesting repair.
Fujitsu does not assume responsibility if data is destroyed during
servicing or repair.