8. Fabricate the power cable as shown below.

How to fabricate power cable TYPCY-2.5

9. In the order shown in figure below, pass the gland nut, flat washers (3 pcs.) and gasket onto

the power cable.

10.As shown in the figure below, fold back the armor onto flat washer (2) and insert remaining

armor through flat washer (3). Cut off the part of the armor that protrudes past the flat washers
(2) and (3).

Passing flat washer, etc. onto power cable

11.Pass the power cable through its cable gland and tighten gland nut.

12.Connect wiring to the terminal TB901, referring to the interconnection diagram.

13.Close the cover that protects pcb 03P9435.

14.Seal the cable gland for the power cable and HV cable with putty.

25 mm

5 mm

FV2-4

Sheath

Armor

Vinyl sheath

Conductor

S = 2.50 mm

2

φ = 2.01 mm

Armor

Sheath

SECTIONAL VIEW

500 mm

(1)

Flat washer

(2) (3)

Cut off armor that
protrudes past washer.

Gasket

Power cable

Gland nut

High voltage is present at the No. 6 pin

of TB901. Miswiring at this pin can

damage the antenna unit.

CAUTION